Odporové a termoelektrické hlavové teploměry

Teploměr sensor type CT AL, Teploměr transmitter type APT AL with Explosion Proof certificate


Material of wetted parts: 304ss or 316Lss (other materials on request)
Process connection: M20x1.5, G1/2", 1/2"NPT, flagnes according to DIN or ANSI (other process connection on request)
Diameter of measuring insert: 6mm, 8mm
Minimal immersion depth: 90mm
Electrical entry: Thread M20x1,5 or 1/2"NPT
Certifikáty ATEX

Další informace ->

Teploměr sensor type CT I4, CT I5


Measuring range: Pt: -50...150°C
Admissible load: OG4 and OG5: 1,6MPa
Material of wetted parts: 304ss or 316Lss (*)
Standard immersion length: Shield of sensor: L=85 or 120 mm (*)
Process connection: M20x1,5 or G1/2"

Další informace ->

Teploměr sensor type CT GB1


Measuring range: Pt: -50...150°C / -196...150°C (*)
Admissible load: see Graph 2 (page IX/ 18)
Material of wetted parts: 304ss or 316Lss (**)
Standard immersion length: L=100, 160, 250, 400 mm (**)
Process connection: M20x1,5 or G1/2"

Další informace ->

Teploměr sensor type CT GN1


Measuring range: Pt: -50...500°C / -196...550°C (*)
Admissible load: see Graph 2 (page IX/ 18)
Material of wetted parts: 304ss or 316Lss (**)
Standard immersion length: L=100, 160, 250, 400 mm (**)
Process connection: M20x1,5 or G1/2"

Další informace ->

Teploměr sensor type CT T1


Measuring range: Pt: -50...500°C / -196...550°C (*)
Admissible load: see Graph 1 (page IX/ 18)
Material of wetted parts: 304ss or 316Lss (**)
Standard immersion length: L=100, 160, 250, 400 mm (**)
Flange process connection

Další informace ->

Teploměr sensor type CT SW1, CT SW2


Measuring range: Pt: -50...500°C for 10H2M, 15HM
Admissible load: see Graph 3 (page IX/ 18)
Material of wetted parts: 15HM, 20H2M (*)
Standard immersion length: L=100, 140, 200 mm (*)

Další informace ->

Teploměr sensor type CT I6, CT I8, CT P1


Measuring range: Pt: -50...500°C / -196...550°C (*)
Admissible load: max. up to 0.1MPa(*****)
Material of wetted parts: CT I6, CT I8 - 304ss or 316Lss (**)
Standard immersion length:
- CT I6, CT I8: L=100, 160, 250, 400 mm (**)
- CT P1: L=500, 700, 1000, 1400, 2000 mm(**)
Process connection:
- CT I6, CT I8: movable fastener UG6, UG8
- CT P1: movable fastener UG15, UC1-15

Další informace ->

Teploměr sensor type CT U1, CT U2, CT U3, CT U4


Measuring range (constant/momentary): J: -40...750°C
Admissible load: 0,1MPa
Material of wetted parts: Heat-resisting steel (*)
Standard immersion length: L=500, 700, 1000,1400, 2000 mm (*)
Process connection: UC1-22, UC2-22

Další informace ->

Teploměr sensor type CT UC


Measuring range (constant/momentary):
- K: -40...1000°C / -40...1100°C
- S: 0...1000°C / 0...1100°C
- B: 600...1000°C / 600...1100°C
Standard immersion length: L=500, 700, 1000, 1400 mm (*)
Process connection: UC1-22, UC2-22

Další informace ->

Teploměr sensor type CT C, CT C1, CT C2, CT C3


Measuring range (constant/momentary):
- K: -40...1000°C / 0...1100°C
- S: 0...1300°C / 0...1600°C
- B: 600...1600°C / 660...1700°C
Admissible load: 0,1MPa
Material of wetted parts: mullite ceramic material 610
Standard immersion length: L=500, 700, 1000, 1400 mm (*)
Process connection: UC1-15, UC2-15, UC1-22, UC2-22

Další informace ->

Teploměr sensor type CT F


Measuring range (constant/momentary): - J: -40...750°C - K: -40...1000°C
Material of wetted parts: holding element heat resisting steel 1.4841(*) measuring element: INCONEL
Standard immersion length: L1, L2 - according to specification (**)
Assembly length for handle S=100 mm or according to specification

Další informace ->

Teploměr sensor type CT X


Measuring range :
- Pt: -50...500°C
- K: -40...750°C
- J: -40...1000°C
Material of wetted parts: 316L - for Pt, Inconel 600 - for thermocouple
Standard immersion length: L- according to specification
Standard lenght of cable: Lk- according to specification

Další informace ->